氣體增壓泵常見問題分析(無動作)
氣體增壓泵經多年使用后,或者經不當使用后,會出現一些影響正常工作的問題。這里就常見的給氣動增壓泵供(gong)驅動(dong)空氣(2-7bar),泵卻(que)無動(dong)作的現(xian)象(xiang)作下分析(xi)。造(zao)成這個問(wen)題的原因大(da)致有三:
999661) 驅(qu)動(dong)(dong)(dong)(dong)部(bu)(bu)分(fen)(fen)(fen)O型圈失效。2) 驅(qu)動(dong)(dong)(dong)(dong)空(kong)氣(qi)太(tai)臟,導(dao)致(zhi)(zhi)驅(qu)動(dong)(dong)(dong)(dong)部(bu)(bu)分(fen)(fen)(fen)不能動(dong)(dong)(dong)(dong)作。3)經常(chang)拆卸而不注意清(qing)(qing)(qing)潔(jie),導(dao)致(zhi)(zhi)驅(qu)動(dong)(dong)(dong)(dong)部(bu)(bu)分(fen)(fen)(fen)不能動(dong)(dong)(dong)(dong)作。相對(dui)應的,解決方(fang)法大致(zhi)(zhi)有(you)三(san):1)更換驅(qu)動(dong)(dong)(dong)(dong)部(bu)(bu)分(fen)(fen)(fen)O型圈。2)清(qing)(qing)(qing)潔(jie)驅(qu)動(dong)(dong)(dong)(dong)部(bu)(bu)分(fen)(fen)(fen)(須(xu)由專業(ye)人(ren)員拆卸、清(qing)(qing)(qing)潔(jie)),并(bing)在(zai)驅(qu)動(dong)(dong)(dong)(dong)氣(qi)路安裝空(kong)氣(qi)過濾器。3)清(qing)(qing)(qing)潔(jie)驅(qu)動(dong)(dong)(dong)(dong)部(bu)(bu)分(fen)(fen)(fen)(須(xu)由專業(ye)人(ren)員拆卸、清(qing)(qing)(qing)潔(jie))。
當前位置:
首頁 >>
公司動態 >>
行業資訊
發布時間:
2014-10-02
上一篇:
D-Pro高壓單向閥選型方法
下一篇:
HIP高壓閥門超高壓連接詳解